800-521-0754

Request Information

CLOSE

PHCbi MCO-80ICL-PA CytoGROW Reach-In Series Large Capacity CO2 Incubator

Item#: MCO-80ICL-PA

The MCO-80ICL-PA CytoGROW ReachIn Series CO2 Incubator by PHC offers greater capacity and more flexibility while providing a precise, consistent temperature, humidity, and CO2 environment to grow a wide variety of cells. The MCO-80IC-PA incubator is ideal for culturing large volumes of biological samples, performing microbiological studies, and working with large volume cell culture apparatus.

FREE SHIPPING ON ALL PHCBI BRAND EQUIPMENT
For a limited time only get FREE Dock-to-Dock freight on all PHCbi equipment. Contact us for a proposal

Request a Quote
  • EXTERIOR DIMENSIONS: 38.6" W x 37.2" D x 80.3" H (986 x 945 x 2040 mm)*
  • INTERIOR DIMENSIONS: 31.7" W x 27.3" D x 60.0" H (806 x 693 x 1524 mm)
  • INTERIOR VOLUME: 30.1 cu.ft. (851 L)
  • OUTER DOOR: Double paned glass door with heater and outer door latch
  • SHELVES: 30.6" x 25.9" (776 x 659 mm)
  • ACCESS PORT: 2: Right and left sides (1.6" (40 mm) diameter)
  • INSULATION: Rigid polyurethane foamed-in-place
  • UV LAMP: Optional
  • NET WEIGHT: 606 lbs (275 kg)
  • TEMPERATURE CONTROL RANGE: Ambient temperature +5ºC to +50ºC
  • TEMPERATURE UNIFORMITY: ±0.50ºC (ambient temperature: 25ºC, setting: 37ºC, CO2: 5 %, no load)
  • MAXIMUM POWER CONSUMPTION: Max 1752 W
  • CO2 CONTROL RANGE: 0% to 20%
  • CO2 CONTROLLER: PID Controller
  • CO2 GAS PRESSURE: 0.1 MPaG (inject):, 15 psiG)
  • CO2 VARIATION: ±0.15% (ambient temperature: 25ºC, setting: 37ºC, CO2: 5%; no load)
  • CO2 SENSOR TYPE: Infrared Sensor
  • DECONTAMINATION METHODS: Optional SafeCell UV light
  • DISPLAY: Digital softkey
  • HUMIDIFYING SYSTEM: Normal mode over 80 (high mode over 90)
  • INTERIOR SURFACES: inCu-saFe stainless steel with copper enriched alloy
  • Horizontal Laminar Airflow System: The cross-shelf directed air flow system promotes optimum temperature uniformity throughout the chamber and contributes to quick temperature recovery after door openings.
  • Humidity Control: Humidity reservoir heaters are located outside the walls of the reservoir. They are not as susceptible to corrosion and scaling from water as competitive systems are. The unit can be set to both nominal (above 80% RH) and high humidity set points (above 90% RH).
  • Heating Method: Heater with fan air circulation, cross shelf laminar air flow.
  • Control & Monitoring: The incubator functions are managed by a fully integrated microprocessor controller with a range of set point, alarm,and programmable inputs that are established through the use of function key.
  • CO2 Recovery: IR2 CO2 sensor with P.I.D. microprocessor control and forced air circulation system delivers fast CO2 recovery characteristics. Exceptionally low CO2 gas consumption rates, less than half of similar competitive units. P.I.D. temperature control with deviation of ±0.1°C.
  • InCu-saFe® Interior: InCu-saFe® forms an integral germicidal barrier against airborne contaminants and helps eliminate mold, spores, and other contaminating spills, while providing a noncorrosive environment.
  • Usability: 30.1 cu.ft. large capacity cabinet allows flexibility in usage. Cabinet will also accommodate a roller bottle apparatus, 5 bottles wide x 7 bottles high (requires mounting ramp kit).
  • Construction: Double paned glass door with outdoor latch, electrogalvanized steel exterior (Acrylic resin baking painted finish), copper alloy stainless steel interior (expect humidifying reservoir), and copper alloy stainless steel shelves (5 standard).
  • Warranty: 3 years parts and labor
Optional Features and Accessories:
Optional Validation Services
  • Validation Documents IQ/OQ
  • Validation Documents IQ/OQ/PQ
  • Pre-delivery Calibration
  • Pre-deliver Temperature Mapping
  • Factory Acceptance Test

CAD Drawing for Model MCO-80ICL-PA Reach-In CO2 Incubator (Laboratory use only)

Download

PHCbi MCO-80ICL-PA CO2 Incubator Product Sheet

Download

PHCBI CO2 & Multigas Incubators Brochure

Download

Mitigating Contamination in the Cell Culture Incubator

Download

PHCbi - Water Jacketed vs Air Jacketed CO2 Incubators

Download

PHCbi Laboratory Equipment Validation Services

Download

PHCBI Cleanroom Appplication Note - Cleanrooms, GMPs & ISO Certification

Download

PHCbi MCO-80ICL-PA CO2 Incubator Operations Manual

Download

PHCbi MCO-80ICL-PA CytoGrow Reach-In Incubator Overview


Request a Proposal