800-521-0754

Request Information

CLOSE

Memmert HCP150 Humidity Chamber | 5.5 cu. ft.

Item#: HCP150

HCP 150 Memmert climate chambers guarantee the perfect atmosphere for climate and temperature tests. High-precision control technology creates controlled and physiologically ideal surroundings for the perfect environment simulation in building physics, electronics, biology, zoology and botany.

 

*Please specify voltage when ordering

$16,944.00 $16,096.80

Request a Quote
  • Volume: 5.5 cu. ft. | 256 L
  • Interior Dimensions W x H x D in (mm): 22" x 27.6" x 15.7" (558.8 x 701.04 x 398.78 mm)
  • Exterior Dimensions W x H x D in (mm): 28.3" x 42.1" x 23.3" (718.82 x 1069.34 x 591.82 mm)
  • Housingcorrosion resistant stainless steel
  • Max. number of internals: 10
  • Max. loading of chamber: 264 lbs (119.75 kgs)
  • Max. loading per internal: 33 lbs (14.97 kgs)
  • Electrical data:
    • 115 Volts: 50/60 Hz /approx. 15.7 A
    • 230 Volts: 50/60 Hz / approx. 7.8 A

Temperature Specs:

  • Setting temperature range: +18 to 90°C
  • Working temperature range without humidity: 6°C up to +90°C
  • Setting accuracy temperature:  0.1°C
  • Temperature sensor: 2 Pt100 sensors Class A in 4-wire-circuit, mutually monitoring and taking over the performance at the same temperature value

Humidity Specs:

  • Setting range humidity: 20 to 95 % rh and rh-Off
  • Setting accuracy humidity: 0.5% rh
  • Humidity: humidity supply with distilled water from external tank by self-priming pump
  • Stainless Steel Exterior: Scratch resistant, hygienic and durable.
  • Warranty: A limited 3 year warranty is included with the option to purchase an extra year.
  • ControlCOCKPIT: TwinDISPLAY. Adaptive multi-functional digital PID-microprocessor controller with 2 high-definition TFT-colour displays.
  • Language Setting: German, English, Spanish, French, Polish, Czech, Hungarian
  • Adjustable Parameters: Temperature (Celsius or Fahrenheit), relative humidity, program time, time zones, summertime/wintertime
  • Timer:  Digital backwards counter with target time setting, adjustable from 1 minute to 99 days
  • Function SetpointWAIT: The process time does not start until the set temperature is reached
  • Calibration: Three freely selectable temperature values
  • Temperature control: mechanical temperature limiter TB, protection class 1 according to DIN 12880 to switch off the heating approx. 10°C above nominal temperature
  • AutoSAFETY: additionally integrated over- and under temperature protection “ASF”, automatically following the setpoint value at a preset tolerance range, alarm in case of over- or under temperature, heating is switched off in case of overtemperature, the compressor in case of under temperature
  • Alarm: with visual and acoustic alarm in case of over-/under temperature and under humidity, open door and empty water tank
  • Temperature control: over- and under temperature monitor TWW, protection class 3.3 or adjustable temperature limiter TWB, protection class 2, adjustable at the controller
  • Autodiagnostic system: integral fault diagnostics for temperature and humidity control

Memmert Humidity Chamber HCP150- Spec Sheet

Download

Memmert Climate Chambers Brochure

Download

Memmert HCP Humidity Chambers Operating Manual

Download

Memmert Constant Climate Chambers HPPeco & Peltier-Cooled Incubators IPPeco


Request a Proposal